Fluke 424D Laser Distance Meter- 100 Meters
Description
Features:
* Fluke 424D Laser Distance Meter supports to measure up to 100 meters accurately & quickly
* Perform other calculations: Area (square feet/meters), Volume, & Pythagoras calculations from 3 different measured values
* Track leveling & height measurements with an inclination of 180-degrees
* Corner angle, built-in compass features makes the technician to accurately record the measurements
* 4-line backlit display
* Addition/Subtraction calculations can be performed
* Includes automated end-piece correction. When measuring from an edge or corner, a built-in sensor detects the position of this bracket and automatically changes the reference point
* Includes audible keypad feedback
* Automatic shut-off feature & battery life supports 5000 measurements
* Measure room's diagonal & horizontal distance from a stable reference point
* Can be fixed on a tripod
* Enables quick recall of 20 measured values
Specifications Overview:
Typical measuring tolerance 1 | ±1.0 mm 3 |
Maximum measuring tolerance 2 | ±2.0 mm 3 |
Range At Leica Target Plate GZM26 | 100 m / 330 ft |
Typical range 1 | 80 m / 260 ft |
Range at unfavorable condition 4 | 60 m / 195 ft |
Smallest unit displayed | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Ø Laser point at distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Measuring tolerance to laser beam 5 | ±0.2° |
Measuring tolerance to housing 5 | ±0.2° |
Range | 360° |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Automatic laser off | After 90 seconds |
Automatic power off | After 180 seconds |
Size (L x W x D) | 127 x 56 x 33 mm |
Weight (with batteries) | 158 g |
Temperature range Storage operation |
-25°C to +70°C (-13°F to +158°F) -10°C to +50°C (14°F to +122°F) |
Maximum relative humidity |
85% at 20°F to 120°F (-7°C to 50°C) |
Note:
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.