Fluke 424D Laser Distance Meter- 100 Meters

₹36,250.00
availability: In Stock

  • Nothing

Description

Features:

* Fluke 424D Laser Distance Meter supports to measure up to 100 meters accurately & quickly

* Perform other calculations: Area (square feet/meters), Volume, & Pythagoras calculations from 3 different measured values

* Track leveling & height measurements with an inclination of 180-degrees

* Corner angle, built-in compass features makes the technician to accurately record the measurements

* 4-line backlit display

* Addition/Subtraction calculations can be performed

* Includes automated end-piece correction. When measuring from an edge or corner, a built-in sensor detects the position of this bracket and automatically changes the reference point

* Includes audible keypad feedback

* Automatic shut-off feature & battery life supports 5000 measurements

* Measure room's diagonal & horizontal distance from a stable reference point

* Can be fixed on a tripod

* Enables quick recall of 20 measured values

Specifications Overview:

Typical measuring tolerance 1 ±1.0 mm 3
Maximum measuring tolerance 2 ±2.0 mm 3
Range At Leica Target Plate GZM26 100 m / 330 ft
Typical range 1 80 m / 260 ft
Range at unfavorable condition 4 60 m / 195 ft
Smallest unit displayed 6 / 30 / 60 mm (10 / 50 / 100 m)
Ø Laser point at distances 6 / 30 / 60 mm (10 / 50 / 100 m)
Measuring tolerance to laser beam 5 ±0.2°
Measuring tolerance to housing 5 ±0.2°
Range 360°
Laser class 2
Laser type 635 nm, < 1 mW
Automatic laser off After 90 seconds
Automatic power off After 180 seconds
Size (L x W x D) 127 x 56 x 33 mm
Weight (with batteries) 158 g
Temperature range Storage operation

-25°C to +70°C (-13°F to +158°F)

-10°C to +50°C (14°F to +122°F)

Maximum relative humidity

85% at 20°F to 120°F (-7°C to 50°C)

Note:

1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.

 

Details